Reinforcement list (Concrete Beam)
Here is a list of the reinforcement settings used for each national annex.
If a reinforcement material lacks a desired diameter a user-defined material can be created. Another option is to provide documentation of the missing material/diameter and that information can be added to the software.
It is possible to add prestressed reinforcement, but since Concrete Beam can't handle prestressing forces it is recommended to use PRE-Stress.
Reinforcement | Reference | Available diameters [mm] | fyk [MPa] | fuk [MPa] | Esk [MPa] | εud [-] | εuk [-] | γs [-] | Bar type |
---|---|---|---|---|---|---|---|---|---|
K500C-T | 6, 8, 10, 12, 14, 16, 20, 25, 32, 36, 40, 42, 46, 50 | 500 | 500 | 200 000 | 0.050 | 0.050 | 1.15 | Ribbed | |
7-wire std | 6.3, 6.4, 8.0, 9.3, 9.6, 11.0, 11.3, 12.5, 12.9, 15.2, 15.3, 15.7 | 1550 | 1770 | 195 000 | 0.045 | 0.045 | 1.15 | Wire | |
7-wire super | 6.3, 6.4, 8.0, 9.3, 9.6, 11.0, 11.3, 12.5, 12.9, 15.2, 15.3, 15.7 | 1630 | 1860 | 195 000 | 0.045 | 0.045 | 1.15 | Wire |
EuroCode, British national Annex
Reinforcement | Reference | Available diameters [mm] | fyk [MPa] | fuk [MPa] | Esk [MPa] | εud [-] | εuk [-] | γs [-] | Bar type |
---|---|---|---|---|---|---|---|---|---|
250 | 6, 8, 10, 12, 14, 16, 20, 25, 32, 36, 40, 42, 46, 50 | 250 | 260 | 200 000 | 0.050 | 0.050 | 1.15 | Plain | |
B500A | 6, 8, 10, 12, 14, 16, 20, 25, 32, 36, 40, 42, 46, 50 | 500 | 500 | 200 000 | 0.050 | 0.050 | 1.15 | Ribbed | |
B500B | 6, 8, 10, 12, 14, 16, 20, 25, 32, 36, 40, 42, 46, 50 | 500 | 500 | 200 000 | 0.050 | 0.050 | 1.15 | Ribbed | |
B500C | 6, 8, 10, 12, 14, 16, 20, 25, 32, 36, 40, 42, 46, 50 | 500 | 500 | 200 000 | 0.050 | 0.050 | 1.15 | Ribbed | |
7-wire std | 6.3, 6.4, 8.0, 9.3, 9.6, 11.0, 11.3, 12.5, 12.9, 15.2, 15.3, 15.7 | 1550 | 1770 | 195 000 | 0.045 | 0.045 | 1.15 | Wire | |
7-wire super | 6.3, 6.4, 8.0, 9.3, 9.6, 11.0, 11.3, 12.5, 12.9, 15.2, 15.3, 15.7 | 1630 | 1860 | 195 000 | 0.045 | 0.045 | 1.15 | Wire | |
420 | 6, 8, 10, 12, 14, 16, 20, 25, 32, 36, 40, 42, 46, 50 | 420 | 420 | 200 000 | 0.050 | 0.050 | 1.15 | Ribbed |
EuroCode, Danish national Annex
Reinforcement | Reference | Available diameters [mm] | fyk [MPa] | fuk [MPa] | Esk [MPa] | εud [-] | εuk [-] | γs [-] | Bar type |
---|---|---|---|---|---|---|---|---|---|
K | 6, 8, 10, 12, 14, 16, 20, 25, 32, 36, 40, 42, 46, 50 | 550 | 550 | 200 000 | 0.050 | 0.050 | 1.20 | Ribbed | |
P | 6, 8, 10, 12, 14, 16, 20, 25, 32, 36, 40, 42, 46, 50 | 550 | 550 | 200 000 | 0.050 | 0.050 | 1.20 | Profiled | |
R | 6, 8, 10, 12, 14, 16, 20, 25, 32, 36, 40, 42, 46, 50 | 235 | 235 | 200 000 | 0.050 | 0.050 | 1.20 | Plain | |
Y | 6, 8, 10, 12, 14, 16, 20, 25, 32, 36, 40, 42, 46, 50 | 550 | 550 | 200 000 | 0.050 | 0.050 | 1.20 | Ribbed | |
Z | 6, 8, 10, 12, 14, 16, 20, 25, 32, 36, 40, 42, 46, 50 | 500 | 500 | 200 000 | 0.050 | 0.050 | 1.20 | Ribbed | |
Kabel 1770/1570 | 6.3, 6.4, 8.0, 9.3, 9.6, 11.0, 11.3, 12.5, 12.9, 15.2, 15.3, 15.7 | 1570 | 1770 | 195 000 | 0.045 | 0.045 | 1.20 | Wire | |
Kabel 1860/1650 | 6.3, 6.4, 8.0, 9.3, 9.6, 11.0, 11.3, 12.5, 12.9, 15.2, 15.3, 15.7 | 1650 | 1860 | 195 000 | 0.045 | 0.045 | 1.20 | Wire |
EuroCode, Finnish national Annex
Reinforcement | Reference | Available diameters [mm] | fyk [MPa] | fuk [MPa] | Esk [MPa] | εud [-] | εuk [-] | γs [-] | Bar type |
---|---|---|---|---|---|---|---|---|---|
S235JRG2 | 6, 8, 10, 12, 14, 16, 20, 25, 32, 36, 40, 42, 46, 50 | 235 | 235 | 200 000 | 0.010 | 0.010 | 1.15 | Plain | |
A500HW | 6, 8, 10, 12, 14, 16, 20, 25, 32, 36, 40, 42, 46, 50 | 500 | 500 | 200 000 | 0.010 | 0.010 | 1.15 | Ribbed | |
A700HW | 6, 8, 10, 12, 14, 16, 20, 25, 32, 36, 40, 42, 46, 50 | 700 | 700 | 200 000 | 0.010 | 0.010 | 1.15 | Ribbed | |
B500K | 4, 5, 6, 7, 8, 9, 10, 11, 12 | 500 | 500 | 200 000 | 0.010 | 0.010 | 1.15 | Profiled | |
B600KX | 3, 4, 5, 6, 7, 8, 9, 10, 11, 12 | 600 | 600 | 200 000 | 0.010 | 0.010 | 1.15 | Profiled | |
B700K | 4, 5, 6, 7, 8, 9, 10, 11, 12 | 700 | 700 | 200 000 | 0.010 | 0.010 | 1.15 | Profiled | |
STD | 6.3, 6.4, 8.0, 9.3, 9.6, 11.0, 11.3, 12.5, 12.9, 15.2, 15.3, 15.7 | 1570 | 1770 | 195 000 | 0.020 | 0.020 | 1.15 | Wire | |
STF_P | 6.3, 6.4, 8.0, 9.3, 9.6, 11.0, 11.3, 12.5, 12.9, 15.2, 15.3, 15.7 | 1470 | 1670 | 195 000 | 0.020 | 0.020 | 1.15 | Wire | |
SUP | 6.3, 6.4, 8.0, 9.3, 9.6, 11.0, 11.3, 12.5, 12.9, 15.2, 15.3, 15.7 | 1630 | 1860 | 195 000 | 0.020 | 0.020 | 1.15 | Wire | |
SUP_P | 6.3, 6.4, 8.0, 9.3, 9.6, 11.0, 11.3, 12.5, 12.9, 15.2, 15.3, 15.7 | 1570 | 1770 | 195 000 | 0.020 | 0.020 | 1.15 | Wire |
EuroCode, Norwegian national Annex
Reinforcement | Reference | Available diameters [mm] | fyk [MPa] | fuk [MPa] | Esk [MPa] | εud [-] | εuk [-] | γs [-] | Bar type |
---|---|---|---|---|---|---|---|---|---|
G250 | 6, 8, 10, 12, 14, 16, 20, 25, 32, 36, 40, 42, 46, 50 | 250 | 250 | 200 000 | 0.050 | 0.050 | 1.15 | Plain | |
B500A | 6, 8, 10, 12, 14, 16, 20, 25, 32, 36, 40, 42, 46, 50 | 500 | 500 | 200 000 | 0.050 | 0.050 | 1.15 | Ribbed | |
B500B | 6, 8, 10, 12, 14, 16, 20, 25, 32, 36, 40, 42, 46, 50 | 500 | 500 | 200 000 | 0.050 | 0.050 | 1.15 | Ribbed | |
B500C | 6, 8, 10, 12, 14, 16, 20, 25, 32, 36, 40, 42, 46, 50 | 500 | 500 | 200 000 | 0.050 | 0.050 | 1.15 | Ribbed | |
Spenntau | 6.3, 6.4, 8.0, 9.3, 9.6, 11.0, 11.3, 12.5, 12.9, 15.2, 15.3, 15.7 | 1630 | 1860 | 195 000 | 0.025 | 0.025 | 1.15 | Wire |
EuroCode, Swedish national Annex
Reinforcement | Reference | Available diameters [mm] | fyk [MPa] | fuk [MPa] | Esk [MPa] | εud [-] | εuk [-] | γs [-] | Bar type |
---|---|---|---|---|---|---|---|---|---|
Ss260 | SS 14 14 11 SS 21 25 11 | 6, 8, 10, 12, 14, 16, 20, 25, 32, 36, 40, 42, 46, 50 | 260 | 260 | 200 000 | 0.050 | 0.050 | 1.15 | Plain |
K500C-T | 6, 8, 10, 12, 14, 16, 20, 25, 32, 36, 40, 42, 46, 50 | 500 | 500 | 200 000 | 0.050 | 0.050 | 1.15 | Ribbed | |
Ks600 | 6, 8, 10, 12, 14, 16, 20, 25, 32, 36, 40, 42, 46, 50 | 600 | 600 | 200 000 | 0.050 | 0.050 | 1.15 | Ribbed | |
Ps500 | 4, 5, 6, 7, 8, 9, 10, 11, 12 | 500 | 500 | 200 000 | 0.050 | 0.050 | 1.15 | Profiled | |
SS3615LR | 6.3, 6.4, 8.0, 9.3, 9.6, 11.0, 11.3, 12.5, 12.9, 15.2, 15.3, 15.7 | 1550 | 1770 | 195 000 | 0.045 | 0.045 | 1.15 | Wire | |
SS3620LR | 6.3, 6.4, 8.0, 9.3, 9.6, 11.0, 11.3, 12.5, 12.9, 15.2, 15.3, 15.7 | 1630 | 1860 | 195 000 | 0.045 | 0.045 | 1.15 | Wire | |
Y1860S7 | SS 21 25 53:2013 | 6.3, 6.4, 8.0, 9.3, 9.6, 11.0, 11.3, 12.5, 12.9, 15.2, 15.3, 15.7 | 1640 | 1860 | 195 000 | 0.0315 | 0.0315 | 1.15 | Wire |
The following list contains outdated reinforcement materials for reference.
Reinforcement | Reference | Available diameters [mm] | fyk [MPa] | fuk [MPa] | Esk [MPa] | εud [-] | εuk [-] | γs [-] | Bar type | In use |
---|---|---|---|---|---|---|---|---|---|---|
Ss 26S, Ss 260S | SS 14 14 11 SS 21 25 11 | 6 - 32 mm | 260 | Plain | 1980 - 2011 1999 - 2011 | |||||
B500B | SS-ENV 10 080 | 6 - 40 mm | 500 | Ribbed | ||||||
Ks600S | SS 14 21 68 SS 21 25 15 | 6 - 25 mm | 600 | Ribbed |
1999-2011 | |||||
Ps 700 | SS 21 25 16 | Profiled | 2001-2011 | |||||||
Ns 500 | SS 14 13 86 SS 21 18 45 SS 21 25 18 | 5 - 12 mm | 500 | Mesh | ||||||
Nps 500 | SS 14 13 87 SS 21 18 45 SS 21 25 19 | 5 - 12 mm | 500 | Mesh | ||||||
B500B | SS-ENV 10 080 | 6 - 16 mm | 500 | Mesh |