Release notes (Punching)
Last modified by Fredrik Lagerström on 2022/01/24 14:04
For Educational version, see here.
Punching 6.5
6.5.000
Released: 2021-02-26
- Fix: For interior columns when no moments are defined an info message has been added informing that no eccentricity factor is calculated (case 9139).
- New: The punching calculation with regard to the Finnish Annex has been adjusted according to " Betongkonstruktioner, anvisningar 2016" (case 75541).
- Fix: The reinforcement has been renamed to K500C-T case( 97505).
- Fix: Reduced the number of requested licenses from Punching (Case 100278).
Punching 6.4
6.4.006
Released: 2018-05-16
- Fix: In a revised version of EC2 the punching capacity together with shear reinforcement has been limited which has been implemented in the program (case 65876).
6.4.005
Released: 2018-04-06
- Fix: When a distance from column to slab edge was defined for corner columns there was no limitation of this value which has been corrected (case 63808).
6.4.004
Released: 2018-02-14
- New: Swedish annex now follows Eurocode standard concerning VRdmax according to EN1992-1-1 6.4.5 (Case 63114).
6.4.003
Released: 2015-06-26
- Updated license handling (added FlexNet support).
6.4.002
Released: 2014-12-19
- Fix: In some cases the reinforcement image was colored blue even when the capacity was not sufficient which is corrected (Case 23386).
6.4.001
Released: 2014-10-22
- Fix: The decimal on values added through in the graphical user interface were sometimes removed.
6.4.000
Released: 2014-04-16
- Fix: Moved all program specific settings and databases to the user profile folder to avoid potential user rights issues.
Punching 6.3
6.3.010
Released: 2016-02-05
- New: Added support for the FlexNet license system.
6.3.009
Released: 2014-10-22
- Fix: The decimal on values added through in the graphical user interface were sometimes removed.
6.3.008
Released: 2014-04-14
- Fix: Moved all program specific settings and databases to the user profile folder to avoid potential user rights issues.
6.3.007
Released: 2013-09-09
- It is from now possible to also define a vct value for the concrete where relevant.
- The following concrete qualities C28/35, C32/40, C54/65 and C58/70 have been added.
- The result including shear reinforcement has been changed to show also the capacity at the column perimeter. Shear reinforcement will only affect the capacity at the control perimeter so in order to secure that an inadequate capacity at the column perimeter is not neglected by mistake this check is now shown also for this result.
6.3.006
Released: 2012-12-21
- Updated the installation file to accomodate the new StruSoft Installer.
6.3.005
Released: 2012-11-30
- Fixed a bug causing the menu option for the manual to be inactive.
6.3.004
Released: 2012-10-02
- Updated the way in which the program handles the layout file for the print engine.
- Updated the module responsible for saving program settings and search paths.
6.3.003
Released: 2012-09-07
- A manual also for Eurocode is now available to the program.
- Updated the way in which user specific settings and data is stored.
6.3.002
Released: 2012-02-20
- New version of the license system (version 3.0.18).
- Updates made to the installtion script pertaining to silent install.
6.3.001
Released: 2012-01-05
- The shear stress at the column perimeter was for the Swedish annex only checked for the standard Vrd,max value and not for the special value used only in this annex which is corrected.
- Capacity with regard to shear reinforcement as bent-down bars is from now on calculated with the assumption of only a single line of bars according to EN 1992-1-1 6.4.5 (1). This means that the ratio d/sr is set to 0.67.
- For shear reinforcement as links an information text according to EN 1992-1-1 9.4.3 has been added.
- The shear stress and capacity for shear reinforcement had wrongly the header force and designation kN which has been changed to stress and kN/m2.
6.3.000
Released: 2011-12-22
- The design for EC2 was wrong if reinforcement was defined as a percentage of the concrete section which is corrected.
- A new license system (version 3.0) has been implemented.